Geotechnical Engineering

Tri-axial Compression Test

Question 1
Marks : +2 | -2
Pass Ratio : 100%
The vertical stress on the solid cylindrical test apparatus is applied by ____________
Major principal stress
Minor principal stress
Intermediate principal stress
All of the mentioned
Explanation:
In tri axial test, the major principle stress σ1 is applied in the vertical direction, and the other two principal stresses σ and σ are applied in the horizontal direction by the fluid pressure round the specimen.
Question 2
Marks : +2 | -2
Pass Ratio : 100%
When the sol is in the state of stress, it is said to be in _____________
Constant state
Plastic equilibrium
Stress conditioned state
Equilibrium condition
Explanation:
When the soil is in the state of stress defined by the equation σ1’= σ3’tan2 α’ + 2c’ tan α’ as principal stress relationship, it is said to be in plastic equilibrium.
Question 3
Marks : +2 | -2
Pass Ratio : 100%
The deviator stress σd is given by __________
σd = σ1 + σ
σd = σ3 – σ1
σd=additional axial load/A2
σd = σ1 – σ3
Explanation:
The deviator stress σd, is given as the ratio of additional axial load to the area A2 at failure or during at any stage of the test.
Question 4
Marks : +2 | -2
Pass Ratio : 100%
Pore pressure developed in the tri axial test can be measured by ____________
Bishop’s apparatus
Pore pressure apparatus
Terzaghi’s apparatus
Mohr’s apparatus
Explanation:
Pore pressure developed in the specimen during the test can be measured with the help of a separate pore pressure measuring equipment such as Bishop’s pore pressure apparatus developed by Bishop in 1950, 1961.
Question 5
Marks : +2 | -2
Pass Ratio : 100%
Which of the following is an advantage of using tri axial test?
Accurate result is not possible
The plane of shear failure is predetermined
Stress conditions are complex
Precise measurement
Explanation:
In tri axial test, precise measurements of the pore pressure and volume change during the test are possible.
Question 6
Marks : +2 | -2
Pass Ratio : 100%
The deviator stress developed in the proving ring, through the applied pressure is equal to are____________
σ1 + σ3
σ1 – σ3
σ2 – σ3
σ2 + σ1
Explanation:
The vertical stress applied by the loading frame, through the proving ring is equal to (σ1 – σ3); this stress difference is called the deviator stress.
Question 7
Marks : +2 | -2
Pass Ratio : 100%
The Tri axial compression test was introduced by __________
A. casagrande and Karl Terzaghi
Mohr
None of the mentioned
All of the mentioned
Explanation:
The tri axial compression test was first introduced in U.S.A by A. casagrande and Karl Terzaghi in 1936-37.
Question 8
Marks : +2 | -2
Pass Ratio : 100%
Bishop’s apparatus does not contain which one of the following equipment?
Porous disc
Top cap
Rollers
All of the mentioned
Explanation:
Bishop’s apparatus mainly consists of the null indicator, the control cylinder, pressure gauge, mercury manometer and burette.
Question 9
Marks : +2 | -2
Pass Ratio : 100%
Which of the following outlet is provided at the base of the tri axial test apparatus?
Cell fluid inlet
Pore water outlet
Drainage outlet
All of the mentioned
Explanation:
Three outlet connections are generally provided through the base of the test apparatus: cell fluid test, pore water outlet from the bottom of the specimen and the drainage outlet from the bottom of the specimen.
Question 10
Marks : +2 | -2
Pass Ratio : 100%
Which of the following strength test is commonly used in the laboratory?
Direct shear test
Confined compression test
Tri axial shear test
Unconfined shear test
Explanation:
As a shear test can be performed under all three drainage condition, tri axial test is most commonly used in research laboratory.